Best liquid level controller online store? The Displacer level controller changes the magnetic float to a float. Displacer level transmitter uses tiny metal film strain sensing technology to measure liquid level, interface or density. Such as Fisher DLC3010 Digital Level Controller. The hydrostatic level controller works by using the measuring principle of hydrostatic pressure. Generally, a silicon pressure sensor is used to convert the measured pressure into an electrical signal. Then it is amplified by the amplifier circuit and compensated by the compensation circuit. Finally, it is output in 4-20ma or 0-10ma current mode. Sino-Inst offers over 10 Ultrasonic Liquid Level Controllers for level measurement. About 50% of these are fuel level meters, 40% is the tank level sensor.
The advantages of ultrasonic liquid level gauge are very outstanding. It is mainly reflected in the following aspects : Adopt non-contact measurement. It is not easily affected by the viscosity and density of the liquid. Of course, the ultrasonic liquid level gauge also has its own limitations and insurmountable defects. Specifically, it is mainly manifested in: There should be no obstacles under the sound wave. Because the ultrasonic liquid level meter uses the principle of sound wave reflection to achieve liquid level measurement. If there are obstacles, it will affect the ultrasonic emission, causing signal loss and affecting the measurement effect.
In the measurement, the ultrasonic pulse is emitted by the sensor (transducer), and the sound wave is reflected by the liquid surface and then received by the same sensor or ultrasonic receiver. Through piezoelectric crystal or magnetostrictive device into electrical signals. The distance between the sensor and the measured liquid surface is calculated by the time between the transmission and reception of sound waves. Discover more details at ultrasonic tank level measurement.
For spherical tanks equipped with a calibrator. The calibration sensor is installed at the center of the calibrator on the outer wall of the tank. If the calibrator is not installed, the calibration sensor should be installed at the height of the outer radius of the tank (equatorial zone). The calibration sensors for the vertical tank and the process tank are installed on the outer side of the tank body, at a height of 0.5m to 1m from the tank bottom. Note: After installing the calibration tube (calibrator) in the tank, the correct installation position should be marked with paint on the outside of the tank wall in time.
Ultrasonic level switch is installed outside the tank. No need to open holes in the tank. Non-Contact Measure. The ideal choice for tank level monitoring. Ultrasonic Level Switch, External Mounted (referred to as “external level switch”) is a new type of level measurement alarm device. Ultrasonic Level Switch is mainly used to detect the liquid level of the storage tank. It can realize the upper and lower limit alarm or monitor whether there is liquid in the pipeline (dry protection). The material of the storage tank can be various metals, non-metals or non-foamed plastics. The wall thickness can be Up to 70mm. See additional details at https://www.drurylandetheatre.com/.