Level measurement instruments supplier factory with kaidi86.com

High quality level measuring instruments manufacturer: Remote Accessibility – Industrial processes often span across intricate and complex facilities. IIoT radar sensors grant operators and engineers the ability to access data remotely eliminating the need for physical proximity to the sensor. This functionality simplifies troubleshooting, reduces response times to irregularities and minimizes periods of inactivity. Predictive Maintenance – One of the advantages of IIoT-enabled radar sensors is their capability to anticipate maintenance requirements. By analyzing data patterns these sensors can forecast when maintenance or calibration will be necessary, allowing for intervention before problems escalate. This predictive maintenance feature significantly improves equipment reliability and lifespan. Read extra info at level measurement instrument.

Humidity interference, when the humidity increases, it will cause the insulator resistance to decrease, the dielectric constant to increase, the skeleton to be fluffy, and the resistance to increase, resulting in an increase in leakage current and changes in capacitance and inductance. Also, it softens the colloid and reduces measurement accuracy. Chemical interference, chemical interference usually refers to some corrosive gases, such as acids and alkalis. The long-term action of these gases will not only damage the instrument and internal components, but also conduct electricity with the metal, affecting the normal operation of the radar level transmitter.

There is AC interference and the voltage is high. For example, for the radar level meter used in the production line, the power supply requirement is 24VDC (typical value), but in the on-site measurement, it is found that the power supply is displayed as 27.2V, which is significantly higher than 24VDC, resulting in a large measurement result and even a radar level meter. crash phenomenon. The installation position of the radar level meter is incorrect, which leads to deviations in the measurement. For example, the accumulation of aggregates in the transfer bin is a “mountain”-shaped cone, but only one radar level meter is installed near the discharge port of the return belt. , the installation position is too close to the discharge opening of the return belt, and at the same time, it is too far from the discharge opening of the feeding belt on both sides. Just below the radar level meter is the drop point of the return belt. If the distance is too close, the aggregate in the falling process will interfere with the radar level meter and form false reflections.

Application conditions, application conditions generally include calm liquid level, slightly fluctuating surface, turbulent surface, with stirring, with foam and so on. The more complex the conditions, the more interference echoes, and the smaller the actual measured range. In a complex environment, a precision radar with strong ability to deal with interference echoes or an antenna with a larger size should be selected.

So what are the installation technical requirements for radar water level meters? The installation of the radar water level meter must be vertical to the object to be measured; there should be no obstructions between the measured object and the radar water level meter, otherwise it will affect the reflection of radar waves, that is, affect the measurement accuracy; the center of the radar water level meter is far from the shore of the water body. The distance must be greater than the radius of the transmitting beam, otherwise the measurement accuracy will also be affected; the installation cantilever bracket of the radar water level meter must be firm, and cannot be shaken up and down; in order to protect the radar water level meter, the water level meter can be installed on the cantilever bracket. Iron box, put the radar water level meter probe.

Level Measurement Solutions for Deaerators: With proper level control and instrumentation, every part of the steam generation cycle can be managed for optimal efficiency. Deaerator Functions: The deaerator serves as an “open” type heat exchanger with its primary function being the removal of oxygen and other corrosive gases from the boiler feedwater. This is accomplished using steam, which can give up about 970 Btu per pound, to support the deaeration process as well as preheat boiler feedwater. Discover additional info on https://www.kaidi86.com/.

So what can be done about these difficulties? Under the condition of strong dust, on the one hand, the radar with high transmitting energy can be selected, on the other hand, the measurement software with continuous measurement algorithm of wave-loss waiting can be selected. When the radar encounters strong dust, it will not misjudge the measurement result even if the radar loses wave for a short time. After entering the state of continuous measurement algorithm, if the reflection wave of real material surface can be recognized within the set waiting time, the correct measurement value of material surface can be obtained. In the past, only a few foreign radars have this function. At present, there are also domestic radars with this function, and the practical application effect is very good.

With emphasis placed on customer satisfaction, innovation, product development and overall business transformation, the company continued to innovate and expand with each passing year. KAIDI has successfully achieved global recognition, obtaining the leading position as Asia’s top process automation sensor manufacturer. In the past 5 years, the company has undergone tremendous growth and development – flourishing internationally and providing customers worldwide with the best customized solutions for process automation. Our Radar Level Meter has a range of up to 150 meters, frequency up to 120GHz and an accuracy of ±1mm, which can cope with various complex measurement conditions.

For the continuous measurement of corrosive, high viscosity, flammable and toxic liquids, liquid-liquid interface and solid-liquid interface that are difficult to measure by ordinary liquid level meter , ultrasonic level meter should be selected, but should not be used in occasions with large liquid level fluctuations . Ultrasonic level meter are suitable for measuring media that can fully reflect and transmit sound waves, but should not be used in vacuum. The ultrasonic flow meter should not be used in process equipment where internal obstacles affect the propagation of sound waves.

In this paper, there are three situations that lead to the radar level meter measurement value jump, respectively, closed metal cover, condensation on the antenna, power supply power supply is insufficient. In fact, the radar level meter measurement value jump belongs to a relatively common problem, leading to the emergence of this problem for a number of reasons, the emergence of problems in a timely manner to find the cause and solve the problem is the most important. Liquid level is the height of the liquid level in a sealed container (pool) or an open container (pool). In addition, liquid level measurement is divided into two categories: continuous measurement and level measurement.